Currency AMD
Substation KTPN-t-63//6/0.4 without HV deadlock – Berezovskij Zavod Podstanciya, OOO | all.biz
Buy Substation KTPN-t-63//6/0.4 without HV deadlock
Substation KTPN-t-63//6/0.4 without HV deadlock
ff8a79f8ec
f0a821a6ed
fb16f0feea
1dee081975
3a7d91941c

Substation KTPN-t-63//6/0.4 without HV deadlock

In stock
Price:
819423.75 AMD
For example: +374(50)123-45-67
Shipping:
Russia, Ekaterinburg
(View map)
+7(3 
Display phones
7
7 years on Allbiz
Technical characteristics
  • BrandБерезовский Завод Подстанция
  • Country of manufactureRussia
Description

Substation KTPN-t-63//6/0.4 without HV deadlock

Appointment Of KTP

Complete transformer substations KTP are intended for converting electricity to reduce high voltage 6 or 10 kV to 380 (220) Volt. They are used to supply industrial and household consumers.

To use 63 Ktpn requires transformer TM 63/10 (6)/0.4

Device KTP

The main element is the step-down transformer substation power transformer (Oily or dry), which through an input device by senior IOC voltage connects to air or cable input high voltage line. From the low voltage switchgear via RUNN to downward transformer connect electricity consumers.

To protect the transfarmatornoj substation KTP from overloads, short circuits and voltage fluctuations apply dischargers and voltage limiters, as well as circuit breakers or switches with fuses.

To prevent electric shock, attendants and others equipment of substation KTP is housed in a metal or concrete casing equipped with electrical and mechanical locks. Enclosure transformer substation KTP is divided into compartments for high voltage equipment and protection switching, step-down transformer and switchgear low voltage.

To monitor the quality of electric power transformer substation are equipped with test equipment (voltage indicators, instruments for measuring voltage and current) and electricity meters.

When installing substation KTP must comply with the following requirements:

  • distance from non-insulated voltage 6-10 kV current-carrying parts shall not be less than 4.5 m and 0.4 kV voltage-not less than 3.5 m.
  • measures should be taken to ensure the passage of vehicles between the CRL and the supports of overhead lines.

LLC "Plant Substation" draws your attention to the related products: transformers with audit TM, CMG, TMZ, ТМН, TRANSFORMER

TM 63 10 04

CMG/10 63 (6)/0.4

Shipping method
Contact the seller
Substation KTPN-t-63//6/0.4 without HV deadlock
Substation KTPN-t-63//6/0.4 without HV deadlock
for
by the goods
Your message must contain at least 20 symbols. The message must not be more than 2000 symbols.
Obligatory field is not filled
The field is wrongly filled
The field is wrongly filled
Compare0